Optical Smoke Detector ES Detect
Product Brochure
Brand | Esser |
Body Material | ABS |
Color | White |
Alarm Current | 9 mA |
Weight | 110 g |
Dimensions | 117x49 mm |
Operating Voltage | 8 to 42 V DC |
Scattered-light smoke detector for reliable early detection of fires. Fire detector with decentralized intelligence, automatic function self-test, automatic environmental adaptation, alarm and operating data storage and alarm display.
A remote indicator can also be connected.
- Part-No.: 800371
- Approval: VdS
System benefits:
- Optimally matched to the ES Line system
- With multisensor detectors for the detection of all fires, even under the most difficult operating conditions
- Up to 30 detectors per detection group
Reliable detection:
- Uniform response sensitivity of the detector for all different types of fire for the multisensor detectors
- Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences
- Automatic adaptation to varying environmental influences
- Electronic compensation also called drift-compensation of long-term influences of contamination or aging
Reliable false alarm suppression:
- High reliability against false alarms by temporal evaluation of different sensor criteria, with built-in insect screen and sealed against rear air flow entry
- Exclusion of signal forms not typical of fires through special filter algorithms
- Automatic self-monitoring of the detector electronics
- Automatic self-monitoring of sensors for function and condition
Maintenance:
- Designation of the heat detector by a black ring on the light pipe
- Hours of operation, alarm and fault counter in each detector
- Operation data retrieval of all detectors of a group with standard service PC and field bus interface
- Detector LED for alarm display and as an identification display in the service (for maintenance with 8000 tools)
Wide range of accessories:
- Standard socket and relay base
- Socket adapter for ceiling installation
- Dust caps optional for fire detectors and detector base
- Kit for suspended mounting
Common technical data:
- Quiescent current: @ 9 V DC 25 μA
- Area to be monitored: 30 m²
- Height to be monitored: 6 m
- Air velocity: 0 m/s ... 25,4 m/s
- Application temperature: -20 to 65 Degree Celsius
- Storage temperature: -25 to 75 Degree Celsius
O2T Multisensor Detector ES Detect
Product Brochure
Material | ABS |
Brand | Esser |
Color | White |
Weight | 110 g |
Size/Dimension | 117x49 mm |
Model Number | O2T |
Multisensor detector with two integrated optical smoke sensors with different scattered light angles as well as additional heat detector sensor evaluation for detecting anything from smoldering fires to open fires with uniform response characteristics. Compares smoke sensor signals for smoke classification and reduction of false alarms from water vapor or dust, for example. Due to its excellent detection properties, the detector is also capable recognizing test fires TF1 and TF6 described in the standard. The O²T multisensor detector is also suitable for higher application temperatures of up to +65° C.
A remote indicator can also be connected.
- Part-No.: 800374
- Approval: VdS
System benefits:
- Optimally matched to the ES Line system
- With multisensor detectors for the detection of all fires, even under the most difficult operating conditions
- Up to 30 detectors per detection group
Reliable detection:
- Uniform response sensitivity of the detector for all different types of fire for the multisensor detectors
- Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences
- Automatic adaptation to varying environmental influences
- Electronic compensation also called drift-compensation of long-term influences of contamination or aging
Reliable false alarm suppression:
- High reliability against false alarms by temporal evaluation of different sensor criteria, with built-in insect screen and sealed against rear air flow entry
- Exclusion of signal forms not typical of fires through special filter algorithms
- Automatic self-monitoring of the detector electronics
- Automatic self-monitoring of sensors for function and condition
Maintenance:
- Designation of the heat detector by a black ring on the light pipe
- Hours of operation, alarm and fault counter in each detector
- Operation data retrieval of all detectors of a group with standard service PC and field bus interface
- Detector LED for alarm display and as an identification display in the service (for maintenance with 8000 tools)
Wide range of accessories:
- Standard socket and relay base
- Socket adapter for ceiling installation
- Dust caps optional for fire detectors and detector base
- Kit for suspended mounting
Common technical data:
- Quiescent current: @ 9 V DC 25 μA
- Area to be monitored: 30 m²
- Height to be monitored: 6 m
- Air velocity: 0 m/s ... 25,4 m/s
- Application temperature: -20 to 65 Degree Celsius
- Storage temperature: -25 to 75 Degree Celsius
Essar 48V Optical Smoke Detector ES Detect
Product Brochure
Brand | Esser |
Body Material | ABS |
Color | White |
Alarm Current | 9 mA |
Weight | 110 g |
Dimensions | 117x49 mm |
Operating Voltage | 48 V |
The threshold value detector with relay contact 800361.10 for object monitoring, comprises an optical smoke detector 800371 from the ES Detect Series and a detector base 805592 which enables a direct connection to a 48 V DC power supply. The detector therefore does not need to be operated in connection with a fire alarm control panel.
If the detector detects a fire alarm, a floating relay contact activates to transmit the alarm. The relay contact is normally closed (NC) by default, but can also be configured as normally open (NO) with a solder strap on the circuit board base.
The smoke detector of Series ES Detect used in the detector base can be reset manually or automatically by a short interruption (4 seconds) of the detector voltage.
A typical use for this detector is to monitor mobile communication stations, e.g. BTS base transceiver stations.
Take note, the detector base with relay output for ES Detect 805592 is included in the scope of delivery!
- Part-No.: 800361.10
System benefits:
- Optimally matched to the ES Line system
- With multisensor detectors for the detection of all fires, even under the most difficult operating conditions
- Up to 30 detectors per detection group
Reliable detection:
- Uniform response sensitivity of the detector for all different types of fire for the multisensor detectors
- Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences
- Automatic adaptation to varying environmental influences
- Electronic compensation also called drift-compensation of long-term influences of contamination or aging
Reliable false alarm suppression:
- High reliability against false alarms by temporal evaluation of different sensor criteria, with built-in insect screen and sealed against rear air flow entry
- Exclusion of signal forms not typical of fires through special filter algorithms
- Automatic self-monitoring of the detector electronics
- Automatic self-monitoring of sensors for function and condition
Maintenance:
- Designation of the heat detector by a black ring on the light pipe
- Hours of operation, alarm and fault counter in each detector
- Operation data retrieval of all detectors of a group with standard service PC and field bus interface
- Detector LED for alarm display and as an identification display in the service (for maintenance with 8000 tools)
Wide range of accessories:
- Standard socket and relay base
- Socket adapter for ceiling installation
- Dust caps optional for fire detectors and detector base
- Kit for suspended mounting
Common technical data:
- Quiescent current approx. 0,051 mA
- Current consumption max. 9 mA Alarm current @ 9 V DC 9 mA
- Contact load relay 30 V DC / 1A, 60 V DC / 0,45 A
- Area to be monitored 110 m²
- Height to be monitored 12 m Air velocity 0 m/s ... 25,4 m/s
- Application temperature -20 to 72 Degree Celsuis
- Storage temperature -25 to 75 Degree Celsuis
- Air humidity < 95 % (non-condensing)
- Type of protection IP 40 with base, up to IP 43 with base and option base)
- Detector specification EN 54-7
Fixed Heat Detector ES Detect
Product Brochure
Brand | Esser |
Alarm Current | 9 mA |
Operating Voltage | 8 to 42 V DC |
Current | 25 mA |
Height To Be Monitored | 7.5 m |
Area To Be Monitored | 30 m2 |
Air Velocity | 0 m/s to 25,4 m/s |
Automatic heat detector with fast semiconductor sensor for reliable detection of fires with distinctive heat. Fire detector with decentralized intelligence, automatic function self-test, alarm and operations data storage and alarm display. A remote indicator can also be connected.
System benefits:
- Optimally matched to the ES Line system
- With multisensor detectors for the detection of all fires, even under the most difficult operating conditions
- Up to 30 detectors per detection group
Reliable detection:
- Uniform response sensitivity of the detector for all different types of fire for the multisensor detectors
- Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences
- Automatic adaptation to varying environmental influences
- Electronic compensation also called drift-compensation of long-term influences of contamination or aging
Reliable false alarm suppression:
- High reliability against false alarms by temporal evaluation of different sensor criteria, with built-in insect screen and sealed against rear air flow entry
- Exclusion of signal forms not typical of fires through special filter algorithms
- Automatic self-monitoring of the detector electronics
- Automatic self-monitoring of sensors for function and condition
Maintenance:
- Designation of the heat detector by a black ring on the light pipe
- Hours of operation, alarm and fault counter in each detector
- Operation data retrieval of all detectors of a group with standard service PC and field bus interface
- Detector LED for alarm display and as an identification display in the service (for maintenance with 8000 tools)
Wide range of accessories:
- Standard socket and relay base
- Socket adapter for ceiling installation
- Dust caps optional for fire detectors and detector base
- Kit for suspended mounting
Details:
- Application temperature -20 °C ... 50 °C
- Storage temperature -25 °C ... 75 °C
- Air humidity < 90 %
- Type of protection IP 40 with base, up to IP 43 with base and option
- Material ABS Color white, similar to RAL 9010
- Weight approx. 110 g
- Detector specification EN 54-5 A1S : 2002
- Dimensions Ø: 117 mm H: 49 mm (62 mm incl. detector base)
OTblue Multisensor Detector ES Detect
Product Brochure
Brand | Esser |
Model Name/Number | OTblue |
Body Material | ABS |
Color | White |
Alarm Current | 9 mA |
Weight | 110 g |
Dimensions | 117x49 mm |
Operating Voltage | 8 to 42 V DC |
Multisensor detector with integrated optical smoke and heat sensor. The optical measurement chamber is equipped with a novel sensor (contains a blue LED transmitter) which allows the detection of open fires, smoldering fires and fires with high heat.
The classical ionization detector is replaced by these detection methods, especially in open fires. This detector is also capable of detecting test fires TF1 and TF6 described in the EN 54-9:1982.
The OTblue multisensor is a fire detector with temporal signal analysis, weighted combination of sensor data, decentralized intelligence, automatic function self-test, automatic environmental adaptation, alarm and operating data storage and alarm display.
A remote indicator can also be connected.
- Part-No.: 800375
- Approval: VdS
System benefits:
- Optimally matched to the ES Line system
- With multisensor detectors for the detection of all fires, even under the most difficult operating conditions
- Up to 30 detectors per detection group
Reliable detection:
- Uniform response sensitivity of the detector for all different types of fire for the multisensor detectors
- Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences
- Automatic adaptation to varying environmental influences
- Electronic compensation also called drift-compensation of long-term influences of contamination or aging
Reliable false alarm suppression:
- High reliability against false alarms by temporal evaluation of different sensor criteria, with built-in insect screen and sealed against rear air flow entry
- Exclusion of signal forms not typical of fires through special filter algorithms
- Automatic self-monitoring of the detector electronics
- Automatic self-monitoring of sensors for function and condition
Maintenance:
- Designation of the heat detector by a black ring on the light pipe
- Hours of operation, alarm and fault counter in each detector
- Operation data retrieval of all detectors of a group with standard service PC and field bus interface
- Detector LED for alarm display and as an identification display in the service (for maintenance with 8000 tools)
Wide range of accessories:
- Standard socket and relay base
- Socket adapter for ceiling installation
- Dust caps optional for fire detectors and detector base
- Kit for suspended mounting
Common technical data:
- Quiescent current: @ 9 V DC 25 μA
- Area to be monitored: 30 m²
- Height to be monitored: 6 m
- Air velocity: 0 m/s ... 25,4 m/s
- Application temperature: -20 to 65 Degree Celsius
- Storage temperature: -25 to 75 Degree Celsius
Class B Fixed Heat Detector ES Detect
Product Brochure
Brand | Esser |
Body Material | ABS |
Color | White |
Dimensions | 117 mm x 49 mm |
Weight | 110 g |
Air Humidity | < 95 % |
Type of Protection | IP 40 |
System benefits:
- Optimally matched to the ES Line system
- With multisensor detectors for the detection of all fires, even under the most difficult operating conditions
- Up to 30 detectors per detection group
Reliable detection:
- Uniform response sensitivity of the detector for all different types of fire for the multisensor detectors
- Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences
- Automatic adaptation to varying environmental influences
- Electronic compensation also called drift-compensation of long-term influences of contamination or aging
Reliable false alarm suppression:
- High reliability against false alarms by temporal evaluation of different sensor criteria, with built-in insect screen and sealed against rear air flow entry
- Exclusion of signal forms not typical of fires through special filter algorithms
- Automatic self-monitoring of the detector electronics
- Automatic self-monitoring of sensors for function and condition
Maintenance:
- Designation of the heat detector by a black ring on the light pipe
- Hours of operation, alarm and fault counter in each detector
- Operation data retrieval of all detectors of a group with standard service PC and field bus interface
- Detector LED for alarm display and as an identification display in the service (for maintenance with 8000 tools)
Wide range of accessories:
- Standard socket and relay base
- Socket adapter for ceiling installation
- Dust caps optional for fire detectors and detector base
- Kit for suspended mounting
Common technical data:
- Operating voltage: 8 ... 42 V DC
- Quiescent current: @ 9 V DC 25 μA
- Alarm current: @ 9 V DC 9 mA
- Area to be monitored: 30 m²
- Height to be monitored: 6 m
- Air velocity: 0 m/s ... 25,4 m/s
- Application temperature: -20 to 65 Degree Celsius
- Storage temperature: -25 to 75 Degree Celsius
Rate-of-rise Detector ES Detect
Brand | Esser |
Body Material | ABS |
Color | White |
Automation Grade | Automatic |
Dimensions | 117 mm x 49 mm |
Alarm Current | 9 mA |
Weight | 110 g |
Operating Voltage | 8 to 42 V DC |
Country of Origin | Made in India |
Automatic heat detector with fast semiconductor sensor for reliable detection of fires with rapid temperature rise and integrated maximum value function for the recognition of fires with slow temperature rises. Fire detector with decentralized intelligence, automatic function self-test, alarm and operations data storage and alarm display.
A remote indicator can also be connected.
- Part-No.: 800271
- Approval: VdS
System benefits:
- Optimally matched to the ES Line system
- With multisensor detectors for the detection of all fires, even under the most difficult operating conditions
- Up to 30 detectors per detection group
Reliable detection:
- Uniform response sensitivity of the detector for all different types of fire for the multisensor detectors
- Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences
- Automatic adaptation to varying environmental influences
- Electronic compensation also called drift-compensation of long-term influences of contamination or aging
Reliable false alarm suppression:
- High reliability against false alarms by temporal evaluation of different sensor criteria, with built-in insect screen and sealed against rear air flow entry
- Exclusion of signal forms not typical of fires through special filter algorithms
- Automatic self-monitoring of the detector electronics
- Automatic self-monitoring of sensors for function and condition
Maintenance:
- Designation of the heat detector by a black ring on the light pipe
- Hours of operation, alarm and fault counter in each detector
- Operation data retrieval of all detectors of a group with standard service PC and field bus interface
- Detector LED for alarm display and as an identification display in the service (for maintenance with 8000 tools)
Wide range of accessories:
- Standard socket and relay base
- Socket adapter for ceiling installation
- Dust caps optional for fire detectors and detector base
- Kit for suspended mounting
Common technical data:
- Quiescent current @ 9 V DC 25 μA
- Area to be monitored 30 m²
- Height to be monitored 7,5 m
- Air velocity 0 m/s ... 25,4 m/s
- Application temperature -20 to 50 Degree Celsuis
- Storage temperature -25 to 75 Degree Celsuis
- Air humidity < 95 % Type of protection IP 40 with base, up to IP 43 with base and option
- Weight approx. 110 g
- Detector specification EN 54-5 A1R
Semi-Automatic Intelligent Non-Addressable Smoke Detectors
Brand | Notifier |
Usage/Application | Office Buildings |
Power Source | Electric |
Automation Grade | Semi-Automatic |
Material | ABS Plastic |
Voltage | 24 V |
Frequency | 50 Hz |
Weight | 300 gm |
Shape | Round |