Product Details:
Brand | Esser |
Body Material | ABS |
Color | White |
Alarm Current | 9 mA |
Weight | 110 g |
Dimensions | 117x49 mm |
Operating Voltage | 8 to 42 V DC |
Scattered-light smoke detector for reliable early detection of fires. Fire detector with decentralized intelligence, automatic function self-test, automatic environmental adaptation, alarm and operating data storage and alarm display.
A remote indicator can also be connected.
System benefits:
Reliable detection:
Reliable false alarm suppression:
Maintenance:
Wide range of accessories:
Product Details:
Material | ABS |
Brand | Esser |
Color | White |
Weight | 110 g |
Size/Dimension | 117x49 mm |
Model Number | O2T |
Multisensor detector with two integrated optical smoke sensors with different scattered light angles as well as additional heat detector sensor evaluation for detecting anything from smoldering fires to open fires with uniform response characteristics. Compares smoke sensor signals for smoke classification and reduction of false alarms from water vapor or dust, for example. Due to its excellent detection properties, the detector is also capable recognizing test fires TF1 and TF6 described in the standard. The O²T multisensor detector is also suitable for higher application temperatures of up to +65° C.
A remote indicator can also be connected.
System benefits:
Reliable detection:
Reliable false alarm suppression:
Maintenance:
Wide range of accessories:
Product Details:
Brand | Esser |
Body Material | ABS |
Color | White |
Alarm Current | 9 mA |
Weight | 110 g |
Dimensions | 117x49 mm |
Operating Voltage | 48 V |
The threshold value detector with relay contact 800361.10 for object monitoring, comprises an optical smoke detector 800371 from the ES Detect Series and a detector base 805592 which enables a direct connection to a 48 V DC power supply. The detector therefore does not need to be operated in connection with a fire alarm control panel.
If the detector detects a fire alarm, a floating relay contact activates to transmit the alarm. The relay contact is normally closed (NC) by default, but can also be configured as normally open (NO) with a solder strap on the circuit board base.
The smoke detector of Series ES Detect used in the detector base can be reset manually or automatically by a short interruption (4 seconds) of the detector voltage.
A typical use for this detector is to monitor mobile communication stations, e.g. BTS base transceiver stations.
Take note, the detector base with relay output for ES Detect 805592 is included in the scope of delivery!
System benefits:
Reliable detection:
Reliable false alarm suppression:
Maintenance:
Wide range of accessories:
Product Details:
Brand | Esser |
Model Name/Number | OTblue |
Body Material | ABS |
Color | White |
Alarm Current | 9 mA |
Weight | 110 g |
Dimensions | 117x49 mm |
Operating Voltage | 8 to 42 V DC |
Multisensor detector with integrated optical smoke and heat sensor. The optical measurement chamber is equipped with a novel sensor (contains a blue LED transmitter) which allows the detection of open fires, smoldering fires and fires with high heat.
The classical ionization detector is replaced by these detection methods, especially in open fires. This detector is also capable of detecting test fires TF1 and TF6 described in the EN 54-9:1982.
The OTblue multisensor is a fire detector with temporal signal analysis, weighted combination of sensor data, decentralized intelligence, automatic function self-test, automatic environmental adaptation, alarm and operating data storage and alarm display.
A remote indicator can also be connected.
System benefits:
Reliable detection:
Reliable false alarm suppression:
Maintenance:
Wide range of accessories:
Product Details:
Brand | Esser |
Alarm Current | 9 mA |
Operating Voltage | 8 to 42 V DC |
Current | 25 mA |
Height To Be Monitored | 7.5 m |
Area To Be Monitored | 30 m2 |
Air Velocity | 0 m/s to 25,4 m/s |
Automatic heat detector with fast semiconductor sensor for reliable detection of fires with distinctive heat. Fire detector with decentralized intelligence, automatic function self-test, alarm and operations data storage and alarm display. A remote indicator can also be connected.
System benefits:
Reliable detection:
Reliable false alarm suppression:
Maintenance:
Wide range of accessories:
Details:
Product Details:
Brand | Esser |
Body Material | ABS |
Color | White |
Dimensions | 117 mm x 49 mm |
Weight | 110 g |
Air Humidity | < 95 % |
Type of Protection | IP 40 |
System benefits:
Reliable detection:
Reliable false alarm suppression:
Maintenance:
Wide range of accessories:
Product Details:
Brand | Esser |
Body Material | ABS |
Color | White |
Automation Grade | Automatic |
Dimensions | 117 mm x 49 mm |
Alarm Current | 9 mA |
Weight | 110 g |
Operating Voltage | 8 to 42 V DC |
Country of Origin | Made in India |
Automatic heat detector with fast semiconductor sensor for reliable detection of fires with rapid temperature rise and integrated maximum value function for the recognition of fires with slow temperature rises. Fire detector with decentralized intelligence, automatic function self-test, alarm and operations data storage and alarm display.
A remote indicator can also be connected.
System benefits:
Reliable detection:
Reliable false alarm suppression:
Maintenance:
Wide range of accessories:
Product Details:
Brand | Notifier |
Usage/Application | Office Buildings |
Power Source | Electric |
Automation Grade | Semi-Automatic |
Material | ABS Plastic |
Voltage | 24 V |
Frequency | 50 Hz |
Weight | 300 gm |
Shape | Round |
4/5
Reviewed by 3 Users
Most Relevant Reviews