Sunrise Fire Private Limited
Sunrise Fire Private Limited
Dhankawadi, Pune, Maharashtra
GST No. 27AAFCG4742F1ZO
TrustSEAL Verified
Call 0804895150358% Response Rate
SEND EMAIL

Single Loop Panel

Manufacturer of a wide range of products which include es line/conventional single loop panel and compact/intelligent addressable control panel.

ES Line/Conventional Single Loop Panel

ES Line/Conventional Single Loop Panel
  • ES Line/Conventional Single Loop Panel
Get Best Quote
Approx. Price: Rs 15,000 / PieceGet Latest Price
Product Brochure

Product Details:

Ambient Temperature-5 Degree Celsius to Degree Celsius
WeightApprox. 5 kg (Without batteries)
DimensionsW: 450 mm H: 320 mm D: 185 mm
Rated Voltage230 V AC
Rated Frequency50 Hz to 60 Hz
Rated Current0.84 A
Output Voltage29 V DC
Battery Capacitymax. 2 x 12 V/12 Ah
Storage Temperature-5 Degree Celsius to 50 Degree Celsius
Air HumidityMore Than 95 %
BrandESSER by Honeywell

Features:
  • 8 sensor groups with up to 30 sensors in each sensor group (conventional panel supports up to 240 conventional devices in total)
  • Large LCD display with 8 rows x 40 characters
  • Integrated sensor group single display
  • Optimized commissioning, maintenance and operation
  • Simple configuration and programming on the keypad
  • Four relays, freely programmable, non-monitored, potential free, max. 30 V DC / 2 A or 60 V DC / 1 A
  • 2 outputs for connecting acoustic or optical sounders according to EN 54-13 (29 V DC/ max. 500 mA)
  • 1 interface to a transmission unit for fire alarm routing equipment (FARE) (12 V DC / max. 200 mA)
  • 1 interface to a transmission unit for fault warnings (12 V DC / max. 200 mA)
  • 1 standard interface extinguisher for fire control system type C according to DIN EN 54-2
  • RS485 for connecting to fire brigade operating panel and fire brigade display panel
  • 1 output UBext 29 V / 0.5A, for power supply of external bus users
  • 72 h emergency current bridge
  • “Delay of relaying” function (PM operating mode according to DIN VDE 0833-2 for preventing false alarms, delay / verify)
  • “2-detection dependency” function (TM operating mode according to DIN VDE 0833-2 for preventing false alarms), alternatively programmable as intermediate alarm storage or 2-zone dependency between the detector zones
  • Operating panel with alphanumerical display
  • Large LCD display with 8 rows x 40 characters
  • Alarm counter for up to 10,000 trips
  • Event memory for up to 10,000 events
Request
Callback
Yes! I am Interested

Compact/Intelligent Addressable Control Panel

Compact/Intelligent Addressable Control Panel
  • Compact/Intelligent Addressable Control Panel
Get Best Quote
Approx. Price: Rs 4,500 / PieceGet Latest Price

Product Details:

BrandEsser By Honeywell
MaterialABS Plastic
IP RatingIP 30
Weight5 kg
Operating Humidity<95 %
Size/DimensionW: 450 mm H: 320 mm D: 185 mm

Features:
  • Single loop panel (system supports up to 127 digital loop addresses in total)
  • Integrated esserbus-PLus (loop powered)
  • Short circuit and open circuit tolerant loop operation with stub cable exits
  • Operation of bus-supplied, synchronously controlled alarm generators (optical/acoustic/voice) in different alarm areas via esserbus-PLus powered loop technology
  • Length of the loop circuit (esserbus) up to 3.5 km
  • Up to 127 esserbus devices (fire detectors or manual call points)/group
  • Up to 32 esserbus transponders
  • Up to 30 IQ8Quad detectors with integrated sounders
  • Up to 20 IQ8Alarm / IQ8Alarm Plus sounder
  • Operation of ATEX approved detectors (intrinsically safe) for potentially explosive areas
  • Optimized commissioning, maintenance and operation
  • Easy configuration and programming of the FACP functions via display
  • 4 relays, programmable, not monitored, potential-free, max. 30 V DC/2 A or 60 V DC/1 A
  • 2 outputs for connection to acoustic and optical sounders according to EN 54-13 (each 24 V DC/max. 500 mA)
  • 1 interface to a transmission unit (TU) for Fire alarm routing equipment (FARE) (12 V DC/max. 200 mA)
  • 1 interface to a transmission unit (TU) for fault reports (12 V DC/max. 200 mA)
  • 1 standard interface solution for fire control type C acc. DIN EN 54-2
  • RS485 for connection of fire brigade control panel and fire brigade graphic annunciator
  • 1 output UBext 24 V/0.5 A, for the voltage supply of external devices
  • 72 hour emergency bypass (depending on configuration)
  • Integrated detector groups individual display
  • Function "delay the transmission" (according to DIN VDE 0833-2, to avoid false alarms, delay/investigate)
  • Function "two-message dependency" (according to DIN VDE 0833-2, to avoid false alarms), alternatively programmable as alarm caching, multi-group dependence or multi-detector dependency
  • Operating panel with alphanumerical display
  • Large LCD display with 8 rows x 40 characters
  • Alarm counter for up to 10,000 trips
  • Event memory for up to 10,000 events

Details:
  • Rated voltage:  230 V AC 
  • Rated frequency  50 Hz ... 60 Hz 
  • Rated current  0,84 A 
  • Output voltage  29 V DC 
  • Quiescent current  approx. 100 mA 
  • Battery capacity  max. 2 x 12 V/12 Ah 
  • Ambient temperature  -5 to 45 Degree Celsuis 
  • Storage temperature  -5 to 50 Degree Celsuis 
 
Request
Callback
Yes! I am Interested
X

Product Videos

Watch More Videos

Explore More Products

View All Products




Reach Us
Sachin Wadagave (Director)
Sunrise Fire Private Limited
Shop No. 11, Kamal Height, Mohan Nagar Bus Stand
Dhankawadi, Pune - 411043, Maharashtra, India


Call Us


Send E-mail