Call 08048951503 82% Response Rate

Send Email

Single Loop Panel

Manufacturer of a wide range of products which include es line/conventional single loop panel and compact/intelligent addressable control panel.
ES Line/Conventional Single Loop Panel

ES Line/Conventional Single Loop Panel

Product Price: Rs 15,000 / PieceGet Best Price

Product Brochure

Product Details:
Ambient Temperature-5 Degree Celsius to Degree Celsius
WeightApprox. 5 kg (Without batteries)
DimensionsW: 450 mm H: 320 mm D: 185 mm
Output Voltage29 V DC
Battery Capacitymax. 2 x 12 V/12 Ah
Rated Frequency50 Hz to 60 Hz
Rated Current0.84 A
Rated Voltage230 V AC
Storage Temperature-5 Degree Celsius to 50 Degree Celsius
Air HumidityMore Than 95 %
BrandESSER by Honeywell
Features:
  • 8 sensor groups with up to 30 sensors in each sensor group (conventional panel supports up to 240 conventional devices in total)
  • Large LCD display with 8 rows x 40 characters
  • Integrated sensor group single display
  • Optimized commissioning, maintenance and operation
  • Simple configuration and programming on the keypad
  • Four relays, freely programmable, non-monitored, potential free, max. 30 V DC / 2 A or 60 V DC / 1 A
  • 2 outputs for connecting acoustic or optical sounders according to EN 54-13 (29 V DC/ max. 500 mA)
  • 1 interface to a transmission unit for fire alarm routing equipment (FARE) (12 V DC / max. 200 mA)
  • 1 interface to a transmission unit for fault warnings (12 V DC / max. 200 mA)
  • 1 standard interface extinguisher for fire control system type C according to DIN EN 54-2
  • RS485 for connecting to fire brigade operating panel and fire brigade display panel
  • 1 output UBext 29 V / 0.5A, for power supply of external bus users
  • 72 h emergency current bridge
  • “Delay of relaying” function (PM operating mode according to DIN VDE 0833-2 for preventing false alarms, delay / verify)
  • “2-detection dependency” function (TM operating mode according to DIN VDE 0833-2 for preventing false alarms), alternatively programmable as intermediate alarm storage or 2-zone dependency between the detector zones
  • Operating panel with alphanumerical display
  • Large LCD display with 8 rows x 40 characters
  • Alarm counter for up to 10,000 trips
  • Event memory for up to 10,000 events
Get Best QuoteRequest A Callback
Compact/Intelligent Addressable Control Panel

Compact/Intelligent Addressable Control Panel

Product Price: Rs 4,500 / PieceGet Best Price

Product Details:
BrandEsser By Honeywell
MaterialABS Plastic
IP RatingIP 30
Weight5 kg
Operating Humidity<95 %
Size/DimensionW: 450 mm H: 320 mm D: 185 mm
Features:
  • Single loop panel (system supports up to 127 digital loop addresses in total)
  • Integrated esserbus-PLus (loop powered)
  • Short circuit and open circuit tolerant loop operation with stub cable exits
  • Operation of bus-supplied, synchronously controlled alarm generators (optical/acoustic/voice) in different alarm areas via esserbus-PLus powered loop technology
  • Length of the loop circuit (esserbus) up to 3.5 km
  • Up to 127 esserbus devices (fire detectors or manual call points)/group
  • Up to 32 esserbus transponders
  • Up to 30 IQ8Quad detectors with integrated sounders
  • Up to 20 IQ8Alarm / IQ8Alarm Plus sounder
  • Operation of ATEX approved detectors (intrinsically safe) for potentially explosive areas
  • Optimized commissioning, maintenance and operation
  • Easy configuration and programming of the FACP functions via display
  • 4 relays, programmable, not monitored, potential-free, max. 30 V DC/2 A or 60 V DC/1 A
  • 2 outputs for connection to acoustic and optical sounders according to EN 54-13 (each 24 V DC/max. 500 mA)
  • 1 interface to a transmission unit (TU) for Fire alarm routing equipment (FARE) (12 V DC/max. 200 mA)
  • 1 interface to a transmission unit (TU) for fault reports (12 V DC/max. 200 mA)
  • 1 standard interface solution for fire control type C acc. DIN EN 54-2
  • RS485 for connection of fire brigade control panel and fire brigade graphic annunciator
  • 1 output UBext 24 V/0.5 A, for the voltage supply of external devices
  • 72 hour emergency bypass (depending on configuration)
  • Integrated detector groups individual display
  • Function "delay the transmission" (according to DIN VDE 0833-2, to avoid false alarms, delay/investigate)
  • Function "two-message dependency" (according to DIN VDE 0833-2, to avoid false alarms), alternatively programmable as alarm caching, multi-group dependence or multi-detector dependency
  • Operating panel with alphanumerical display
  • Large LCD display with 8 rows x 40 characters
  • Alarm counter for up to 10,000 trips
  • Event memory for up to 10,000 events

Details:
  • Rated voltage:  230 V AC 
  • Rated frequency  50 Hz ... 60 Hz 
  • Rated current  0,84 A 
  • Output voltage  29 V DC 
  • Quiescent current  approx. 100 mA 
  • Battery capacity  max. 2 x 12 V/12 Ah 
  • Ambient temperature  -5 to 45 Degree Celsuis 
  • Storage temperature  -5 to 50 Degree Celsuis 
 