- Home
- ยป
- Our Products
- »
- Suppression Release Panel & System
Suppression Release Panel & System
Pyrox Fire Panel
Minimum Order Quantity: 1 Piece
Product Type | Fully Addressable Fire Alarm Cum Public Address System For Large Infrastructure |
Usage/Application | Commercial |
Brand | Pyrox Fire Panel |
Zones | 1 to 10 |
Model Name/Number | Victofire 7000 |
Voltage | Power Supply1: Input: 230VAC +10% -15%, 50Hz; Output:12VDC, 5A;5VDC, 5A. |
Material | Metal |
Color | White / Grey |
Country of Origin | Made in India |
Number of Devices per Loop: 254
10 Conventional Sounder Outputs
Loop Communication Protocols Supported: Sensortec AS -NITTAN
Power Supply1: Input: 230VAC +10% -15%, 50Hz; Output:12VDC, 5A;5VDC, 5A.
Contact No:-
Additional Information:
- Production Capacity: 100
- Packaging Details: Box
Novec 1230 Fire Suppression System
Usage/Application | Industrial |
Fire Extinguisher Type | Novac 1230 |
Color | Red |
Certification | UL & FM Approved |
Body Material | Mild Steel |
Finishing | Powder Coated |
Model Name/Number | Novec 1230 |
Brand | Firetrace |
Country of Origin | Made in India |
Novec 1230 Fire Suppression System a fire before it starts by rapidly removing heat. In a typical total flooding system, the fluid is stored as a liquid in cylinders pressurized with nitrogen. Automatic detection sensors trigger release when the fire is at the incipient stage, extinguishing it in mere seconds.Novec 1230 fluid evaporates 50 times faster than water. In fact, you could soak a paperback book in a bath of Novec 1230 fluid and within a minute, pick it up and read where you left off.
In this video you’ll see a controlled test of a fire in a simulated data center. Watch to compare the performance of Novec 1230 fluid to a water sprinkler system.
FM-200 Fire Suppression System
Brand | Firetrace |
Capacity | 15 kg |
Usage/Application | Industrial |
Material | Mild Steel |
Fire Suppression Type | Cylinder |
Certification | Ul & FM Approved |
Model Name/Number | FM-200 |
Finishing | Powder Coated |
Color | Red |
FM-200™ suppresses fire by disrupting the fire triangle. The fire triangle is made up of heat, oxygen, and a fuel source, and by removing one of these elements, the fire is extinguished. FM-200™ removes the heat or free radicals, which interferes with the fire triangle's chemical reaction to extinguish the fire. Clean agent fire suppression systems, like ones using FM-200™, can achieve fire extinguishing concentrations in 10 seconds or less.
How does FM-200™ work?
FM-200™ suppresses fire by disrupting the fire triangle. The fire triangle is made up of heat, oxygen, and a fuel source, and by removing one of these elements, the fire is extinguished. FM-200™ removes the heat or free radicals, which interferes with the fire triangle's chemical reaction to extinguish the fire. Clean agent fire suppression systems, like ones using FM-200™, can achieve fire extinguishing concentrations in 10 seconds or less.
FM-200™ advantages:
- FM-200™ is a clean agent that is safe around people; therefore, FM-200™ fire suppression systems are safe to install in occupied spaces.
- When an FM-200™ fire suppression system activates to put out a fire, no residue is left behind, and it is safe for equipment, electronics, and machinery.
- Compared to other clean agents like Novec 1230, FM-200™ is a slightly more cost-effective option.
- Because of the small amount of FM-200™ required to suppress a fire, smaller or fewer cylinders are needed when compared to other agents like Novec 1230.
Simplex 4004R Suppression Release Panel
Product Brochure
Brand | Simplex |
Material | Metal |
Voltage | 220 V |
Weight | 400 gm |
Frequency | 50 Hz |
Automation Grade | Semi-Automatic |
Model Name/Number | 4004R |
-
- Four initiating device circuits (IDCs)
- Two notification appliance circuits (NACs)
- Two releasing appliance circuits (RACs)
- Two special purpose monitor inputs (SPMs) that accept manual release request and manual abort request for Agent Release systems, and waterflow and supervisory for Preaction or Deluge systems
- Three auxiliary relays with selectable functions
Suppression release operation - Supported release modes include:
-
- Automatic extinguishing release
- Deluge and preaction sprinkler system release
- Dual or single hazard area protection
- Combined agent release and preaction operation
Audible Escalation of Events - Stage 1 activates Temporal or 20 bpm March Time pattern; Stage 2 activates 120 bpm March Time pattern to indicate release timer active; Release activates On Steady to indicate release timer expired and actuator is activated.
Event Log - A 50-point historical log allows you to investigate the cause of a release after the event.
Flexible Programming - The 4004R can be programmed from the ront panel or from a PC.
Fm 200 Fire Suppression System
Usage/Application | Industrial |
Material | MS |
Brand | Firetrace |
Cylinder Size | 200 liter |
Model Name/Number | Fm 200 |
Color | Red |
Is It Portable | Portable |
Fm 200 Fire Suppression System: BoAGas detecting and monitoring equipment for life. Range of Fixed & Portable for industrial, commercial & residential safety. Available in indoor/outdoor, flameproof such Communication.